Figure Q3(c) shows a typical unit for an affordable home. As an M\&E consultant, you are required to plan and design lig

Business, Finance, Economics, Accounting, Operations Management, Computer Science, Electrical Engineering, Mechanical Engineering, Civil Engineering, Chemical Engineering, Algebra, Precalculus, Statistics and Probabilty, Advanced Math, Physics, Chemistry, Biology, Nursing, Psychology, Certifications, Tests, Prep, and more.
Post Reply
answerhappygod
Site Admin
Posts: 899604
Joined: Mon Aug 02, 2021 8:13 am

Figure Q3(c) shows a typical unit for an affordable home. As an M\&E consultant, you are required to plan and design lig

Post by answerhappygod »

Figure Q3 C Shows A Typical Unit For An Affordable Home As An M E Consultant You Are Required To Plan And Design Lig 1
Figure Q3 C Shows A Typical Unit For An Affordable Home As An M E Consultant You Are Required To Plan And Design Lig 1 (44.66 KiB) Viewed 47 times
Figure Q3(c) shows a typical unit for an affordable home. As an M\&E consultant, you are required to plan and design lighting and electrical system for its development. This house is to be illuminated and the illuminance required is 200Lux. Assuming a standard maintenance factor and utilisation factor of 0.6 for the lighting scheme. If 36 W fluorescent lamps ( 75 lumens/watt) are used, suggest and determine the number of fluorescent lamps required for the whole house.
(AREA : 850sqft,79.00sq meter) Figure Q3(c)
(d) A windowless office is to be illuminated for 12 hours per day, for 5 days per week, for 50 weeks per year. The floor is 30 m long and 10 m wide. An overall illumination of 450Lux is to be maintained over the whole floor. The total light loss factor for the installation is 70 %. The designers have the choice of using 100 W tungsten filament lamps, which have an efficacy of 12 lm/W and need replacing every 3000 hours, or 65 W tubular fluorescent warm white lamps, which have an initial output of 5400 lm and are expected to provide 12000 hours of service. The room layout requires an even number of lamps. Electricity costs RM 0.22/kWh. The tungsten lamps cost RM1.00 each while the fluorescent tubes cost RM10.00 each. (i) Determine the total costs per year for lighting system which is designed with tungsten lamps. (ii) Determine the total costs per year for lighting system which is designed with fluorescent lamps.
Join a community of subject matter experts. Register for FREE to view solutions, replies, and use search function. Request answer by replying!
Post Reply