- L = 0.2m ri = 0.015m Tb = 50°C Ty = 28°C h = 6 W/mK k = 0.35 W/mK 0 = 17.5 A = 0.078 2k Critical Thickness to h 0.116

Business, Finance, Economics, Accounting, Operations Management, Computer Science, Electrical Engineering, Mechanical Engineering, Civil Engineering, Chemical Engineering, Algebra, Precalculus, Statistics and Probabilty, Advanced Math, Physics, Chemistry, Biology, Nursing, Psychology, Certifications, Tests, Prep, and more.
Post Reply
answerhappygod
Site Admin
Posts: 899604
Joined: Mon Aug 02, 2021 8:13 am

- L = 0.2m ri = 0.015m Tb = 50°C Ty = 28°C h = 6 W/mK k = 0.35 W/mK 0 = 17.5 A = 0.078 2k Critical Thickness to h 0.116

Post by answerhappygod »

L 0 2m Ri 0 015m Tb 50 C Ty 28 C H 6 W Mk K 0 35 W Mk 0 17 5 A 0 078 2k Critical Thickness To H 0 116 1
L 0 2m Ri 0 015m Tb 50 C Ty 28 C H 6 W Mk K 0 35 W Mk 0 17 5 A 0 078 2k Critical Thickness To H 0 116 1 (44.09 KiB) Viewed 43 times
L 0 2m Ri 0 015m Tb 50 C Ty 28 C H 6 W Mk K 0 35 W Mk 0 17 5 A 0 078 2k Critical Thickness To H 0 116 2
L 0 2m Ri 0 015m Tb 50 C Ty 28 C H 6 W Mk K 0 35 W Mk 0 17 5 A 0 078 2k Critical Thickness To H 0 116 2 (44.09 KiB) Viewed 43 times
Hand written
- L = 0.2m ri = 0.015m Tb = 50°C Ty = 28°C h = 6 W/mK k = 0.35 W/mK 0 = 17.5 A = 0.078 2k Critical Thickness to h 0.116 А ri = 0.078 471 0.078 47 Thickness = x ro - ri where ro is solved from following equation 17 Ankh To - Ty e 73 + hry - k = 0 4 kr Heat flow without insulation e = hA(To - Ty) = 6 x 0.078(50 - 28) = 10.296 - + To - Ti 1 R = 4rtkror: 4trh To - Ty Heat flow with insulation Q = R