21 Estimate the contaminant removal rate (in the presence of free-product phase) Recently, a gasoline spill occurred at

Business, Finance, Economics, Accounting, Operations Management, Computer Science, Electrical Engineering, Mechanical Engineering, Civil Engineering, Chemical Engineering, Algebra, Precalculus, Statistics and Probabilty, Advanced Math, Physics, Chemistry, Biology, Nursing, Psychology, Certifications, Tests, Prep, and more.
Post Reply
answerhappygod
Site Admin
Posts: 899604
Joined: Mon Aug 02, 2021 8:13 am

21 Estimate the contaminant removal rate (in the presence of free-product phase) Recently, a gasoline spill occurred at

Post by answerhappygod »

21 Estimate The Contaminant Removal Rate In The Presence Of Free Product Phase Recently A Gasoline Spill Occurred At 1
21 Estimate The Contaminant Removal Rate In The Presence Of Free Product Phase Recently A Gasoline Spill Occurred At 1 (138.69 KiB) Viewed 34 times
21 Estimate the contaminant removal rate (in the presence of free-product phase) Recently, a gasoline spill occurred at a gasoline station and caused subsurface contamination. A soil venting well was installed at the site for remediation . A The following data were obtained from the remedial investigation and a pilot test: Pressure at the extraction well-09 atm Pressure at a monitoring well 30 ft away from the venting well - 0.95 atm Diameter of the venting well - 4 in Permeability of the formation - 1 Darcy Well screen length - 20 ft Viscosity of air -0.018 centipoise Temperature of the formation -20°C Estimate the contaminant removal rate at the beginning of the project. Q2 Estimate the contaminant removal rate in the absence of the free-product phase) A subsurface is contaminated with benzene. The average benzene concen tration of the soil samples, taken from the contaminated zone, was 500 mg/kg. The following data were obtained from the remedial investigation and a pilot test: Pressure at the extraction well - 0.9 atm Pressure at a monitoring well 30 ft away from the venting well - 0.95 atm Diameter of the venting well - 4 in Permeability of the formation=1 Darcy Well screen length - 20 ft Viscosity of air -0.018 centipoise Porosity -0.35 Organic content = 0.03 Water saturation = 45% Subsurface temperature -25°C Bulk density of soil - 1.7 g/cm Estimate the contaminant removal rate at the beginning of the project
Join a community of subject matter experts. Register for FREE to view solutions, replies, and use search function. Request answer by replying!