MALTEPE UNIVERSITY/FACULTY OF ARCHITECTURE AND DESIGN ARCH 266/ENVIRONMENTAL CONTROL SYSTEMS Calculation of the Heat Loa

Business, Finance, Economics, Accounting, Operations Management, Computer Science, Electrical Engineering, Mechanical Engineering, Civil Engineering, Chemical Engineering, Algebra, Precalculus, Statistics and Probabilty, Advanced Math, Physics, Chemistry, Biology, Nursing, Psychology, Certifications, Tests, Prep, and more.
Post Reply
answerhappygod
Site Admin
Posts: 899603
Joined: Mon Aug 02, 2021 8:13 am

MALTEPE UNIVERSITY/FACULTY OF ARCHITECTURE AND DESIGN ARCH 266/ENVIRONMENTAL CONTROL SYSTEMS Calculation of the Heat Loa

Post by answerhappygod »

Maltepe University Faculty Of Architecture And Design Arch 266 Environmental Control Systems Calculation Of The Heat Loa 1
Maltepe University Faculty Of Architecture And Design Arch 266 Environmental Control Systems Calculation Of The Heat Loa 1 (34.5 KiB) Viewed 29 times
Maltepe University Faculty Of Architecture And Design Arch 266 Environmental Control Systems Calculation Of The Heat Loa 2
Maltepe University Faculty Of Architecture And Design Arch 266 Environmental Control Systems Calculation Of The Heat Loa 2 (44.74 KiB) Viewed 29 times
Maltepe University Faculty Of Architecture And Design Arch 266 Environmental Control Systems Calculation Of The Heat Loa 3
Maltepe University Faculty Of Architecture And Design Arch 266 Environmental Control Systems Calculation Of The Heat Loa 3 (25.95 KiB) Viewed 29 times
MALTEPE UNIVERSITY/FACULTY OF ARCHITECTURE AND DESIGN ARCH 266/ENVIRONMENTAL CONTROL SYSTEMS Calculation of the Heat Load PROJECT I: Calculate the heat load for the structure given below. Location: Istanbul, Outdoor temperature (-3°C) PI P2 Details of P5 P3 bedroom 20° living room 20° Details of P1-P2 P3-P4 building hall 15 100 75 hall 18 bathroom 240 kitchen 22 P4 Elevation for window Window type: Plastic frame Double glaring Air ap: 12 mm PS Details of door Door information: Wooden Sash Single glaced CS Scanned with CamScanner
NO Structure of the outer walls Material Name 1 Inner Mortar 2 Brick 3 Heat Insulation 4 Brick 5 Outer mortar Thickness, L (m) 0.02 0.085 0.05 0085 0.03 Thermal Conductivity, 2 (W/m.K) 087 0.45 0.04 0.45 1.40 Structure of the inner walls NO Material Name 1 Inner Mortar 2 Brick Inner Mortar Thickness, L. (m) 0.02 0.10 0.02 Thermal Conductivity, 2 (W/m.K) 0.87 0.45 0.87 Thickness, L (m) Structure of the bathroom Wall NO Material Name 1 Inner Mortar 2 Brick 3 Gluing mortar 4 Ceramic 0.02 0.20 0.03 0.007 Thermal Conductivity. 2 (W/m.K) 0.87 0.45 1.40 1.04 Structure of the floorings (bedroom-living room) NO Material Name Thickness, L (m) 1 Wood flooring 0.03 2 Topping coat 0.04 3 Reinforced concrete floor 0.12 4 Ceiling mortar 0.02 Thermal Conductivity, 2 (W/m.K) 0.20 1.40 2.10 0.87 Structure of the floorings (kitchen-hall-bathroom) NO Material Name Thickness, L (m) I Ceramic 0.007 2 Topping coal 0.04 3 Reinforced concrete floor 0.12 4 Ceiling mortar 0.02 Thermal Conductivity. 2 (W/m.K) 1.04 1,40 2.10 0.87 CS Scanned with CamScanner
Overall heat transfer coef. of different types of windows and doors DOUBLE GLAZED DOUBLE GLAZED Overall Heat SINGLE WINDOWS WINDOWS WITH LOW-E Transfer Coer. GLAZED (without coating) COATING (U) (W/m°C) WINDOWS AIR GAP (mm) AIR GAP (mm) 12 16 12 16 Without Sash 6,7 2.9 2,7 1.6 1.3 Wooden Sash 4,57 2.64 2,5 1,74 1.53 Plastic Sash 4,73 2.79 2.65 1.89 1.68 (2 rooms) Plastic Sash 4,63 2,70 2.56 1.80 1.59 (3 rooms) Plastic Sash 4.60 2.67 2.53 1.77 1.56 (4 rooms) Aluminium 5,62 3.68 3.55 2,79 2.58 Sash CS Scanned with CamScanner
Join a community of subject matter experts. Register for FREE to view solutions, replies, and use search function. Request answer by replying!