Steel Beam (B1) supporting floor above the restaurant, span between supports 3150mm. Grade of steel to be S275 to suppor

Business, Finance, Economics, Accounting, Operations Management, Computer Science, Electrical Engineering, Mechanical Engineering, Civil Engineering, Chemical Engineering, Algebra, Precalculus, Statistics and Probabilty, Advanced Math, Physics, Chemistry, Biology, Nursing, Psychology, Certifications, Tests, Prep, and more.
Post Reply
answerhappygod
Site Admin
Posts: 899603
Joined: Mon Aug 02, 2021 8:13 am

Steel Beam (B1) supporting floor above the restaurant, span between supports 3150mm. Grade of steel to be S275 to suppor

Post by answerhappygod »

Steel Beam B1 Supporting Floor Above The Restaurant Span Between Supports 3150mm Grade Of Steel To Be S275 To Suppor 1
Steel Beam B1 Supporting Floor Above The Restaurant Span Between Supports 3150mm Grade Of Steel To Be S275 To Suppor 1 (278.7 KiB) Viewed 43 times
Steel Beam (B1) supporting floor above the restaurant, span between supports 3150mm. Grade of steel to be S275 to support the given loads above on the project brief. Assume the beam is fully laterally restrained and that it sits on 100mm bearings at one end and 150 mm bearing at the other end. Ignore the self-weight of the beam. Beam is simple supported and supports UDL at full span and point load at mid span. = Loading - K Pitch roof areas (snow) = 0.75KN/m2 First and Second Floor Terrace = 1.5KN/m2 Wine bar and restaurant Floors = 4.OKN/m2 = Loading - WK Basic wind speed 46m/sec (outskirts of small town) = Loading - gk Roof - including tiles, battens, felt and the trusses. 1.2KN/m2 Floors – timber – including - ceilings = 1KN/m2 Terrace floor – concrete - including waterproofing = 4KN/m2 = a) Design suitable steel section (B1) supporting floor above the restaurant. Establish the maximum applied Bending Moment and Shear Force, using any of the following method (Formulae, Shear Moment Diagram or Equilibrium Equations). b) Check strength classification, the resistance of the section c) Check the bearing at the support under the steel beam d) Check deflection

Sketch Drawings Not to scale EXISTING TILES ON TIMBER ROOF STRUCTURE W3 RESIDENTIAL y 2nd FLOOR (W1 атор RESIDENTIM TERRAC ÁCB) TFD. B1 PROPOSUD NEW RESTAURANT. ST FLOOR W2 Y GROND FLOOR PROPESE NEW WINE BAR. BASEMENT 18 EXTENSION Tc EXISTING BUILDING P Ref. © > But TS Extansi Carte Pow) 6710 iBel () so ho 2017 | Bustment Plan Timber ST New Con for ' Ekim Flee Cover) now So existing (ve vive Frekaring Ground Floor Pla 1.800 D Cew Terrace Now CUF IS Ploor Plan 2 No now Eximba food Faber foor span of Plaan tweet Rest Scale . If yot
Join a community of subject matter experts. Register for FREE to view solutions, replies, and use search function. Request answer by replying!
Post Reply