QI Figure Q1(a) shows the first floor structural layout plan for a factory-office building and Figure Q1(b) shows the de

Business, Finance, Economics, Accounting, Operations Management, Computer Science, Electrical Engineering, Mechanical Engineering, Civil Engineering, Chemical Engineering, Algebra, Precalculus, Statistics and Probabilty, Advanced Math, Physics, Chemistry, Biology, Nursing, Psychology, Certifications, Tests, Prep, and more.
Post Reply
answerhappygod
Site Admin
Posts: 899603
Joined: Mon Aug 02, 2021 8:13 am

QI Figure Q1(a) shows the first floor structural layout plan for a factory-office building and Figure Q1(b) shows the de

Post by answerhappygod »

Qi Figure Q1 A Shows The First Floor Structural Layout Plan For A Factory Office Building And Figure Q1 B Shows The De 1
Qi Figure Q1 A Shows The First Floor Structural Layout Plan For A Factory Office Building And Figure Q1 B Shows The De 1 (28.87 KiB) Viewed 65 times
Qi Figure Q1 A Shows The First Floor Structural Layout Plan For A Factory Office Building And Figure Q1 B Shows The De 2
Qi Figure Q1 A Shows The First Floor Structural Layout Plan For A Factory Office Building And Figure Q1 B Shows The De 2 (17.38 KiB) Viewed 65 times
Qi Figure Q1 A Shows The First Floor Structural Layout Plan For A Factory Office Building And Figure Q1 B Shows The De 3
Qi Figure Q1 A Shows The First Floor Structural Layout Plan For A Factory Office Building And Figure Q1 B Shows The De 3 (16.49 KiB) Viewed 65 times
QI Figure Q1(a) shows the first floor structural layout plan for a factory-office building and Figure Q1(b) shows the detailing of beam 1/A-B. The brickwall of 3.5 m height is construct on the beams perimeter (A0/1-2, B/1-2, 1/A0-B and 2/A0-B). Other design data are as follows: All slabs thickness All beams size Characteristic strength of concrete Characteristic strength of steel reinforcement= Unit weight of reinforced concrete Finishes and services Brickwall Variable action (b) 150 mm 250 x 750 mm (c) = 30 MPa 1.5 kN/m² 2.6 kN/m² = 3.0 kN/m² (a) Illustrate the load cases to be considered in designing beam 1/A-B. 500 MPa 25 kN/m² (5 marks) Identify and analyse one of the load case in Q1(a) that will cause maximum sagging moment at span 1/A-B. (20 marks) Based on the analysis in Q1(b) and Figure Q1(b), check if the shear link near support B is adequate. (10 marks)
(AO) 50 mm] 2m H10-250 c/c H10-250- 2125 2H25 250 mm 2H25 3125 A Section 1-1 Ignore for calculation 700 mm 750 mm F 8 m H10-250 cc 50 mm] H10-250- -3H25 Detailing of Beam 1/A-B 2H25 250 mm 2H25 2H25 Section 2-2 2H25- OOL F2 Ignore for calculation 750 mm B
2 (1 6m AO A 2m 1 11 11 11 11 11 11 11 11 11 11 4 m (A1 4m Notes: 1. All First Floor Beams To Be 250 mm x 750 mm 2. All First Floor Slabs To Be 150 mm Thick FIGURE Q1(a) B
Join a community of subject matter experts. Register for FREE to view solutions, replies, and use search function. Request answer by replying!
Post Reply