Question 2 (40%) Fig. 1 - Double Acting Cyliners with reed position sensors and Control Box Cylinder A a0 al Cylinder B

Business, Finance, Economics, Accounting, Operations Management, Computer Science, Electrical Engineering, Mechanical Engineering, Civil Engineering, Chemical Engineering, Algebra, Precalculus, Statistics and Probabilty, Advanced Math, Physics, Chemistry, Biology, Nursing, Psychology, Certifications, Tests, Prep, and more.
Post Reply
answerhappygod
Site Admin
Posts: 899603
Joined: Mon Aug 02, 2021 8:13 am

Question 2 (40%) Fig. 1 - Double Acting Cyliners with reed position sensors and Control Box Cylinder A a0 al Cylinder B

Post by answerhappygod »

Question 2 40 Fig 1 Double Acting Cyliners With Reed Position Sensors And Control Box Cylinder A A0 Al Cylinder B 1
Question 2 40 Fig 1 Double Acting Cyliners With Reed Position Sensors And Control Box Cylinder A A0 Al Cylinder B 1 (67.27 KiB) Viewed 25 times
Question 2 40 Fig 1 Double Acting Cyliners With Reed Position Sensors And Control Box Cylinder A A0 Al Cylinder B 2
Question 2 40 Fig 1 Double Acting Cyliners With Reed Position Sensors And Control Box Cylinder A A0 Al Cylinder B 2 (84.02 KiB) Viewed 25 times
Question 2 40 Fig 1 Double Acting Cyliners With Reed Position Sensors And Control Box Cylinder A A0 Al Cylinder B 3
Question 2 40 Fig 1 Double Acting Cyliners With Reed Position Sensors And Control Box Cylinder A A0 Al Cylinder B 3 (85.36 KiB) Viewed 25 times
Question 2 (40%) Fig. 1 - Double Acting Cyliners with reed position sensors and Control Box Cylinder A a0 al Cylinder B b0 bi SOL A+ SOLA A- SOL B+ SOL B- 1/1/12 1111 Fig. 2 - Electro-pneumatic sub-circuit diagram

Power 24V 24V 24V > 24V) 24V Terminal No. X40 X412 X42- X43 X442 X45 X46 X47 СОме Y40 Y412 Y422 Y43 Y440 Y45 Y46 СОме Description a0 - Cylinder A Retraction (NO) al - Cylinder A Extension (NO) bo-Cylinder B Retraction (NO) bl - Cylinder B Extension (NO) PBO (NO) PB1 (NO) PB2 (NO) PB3 (NO) 247+) Bulb (Red) Bulb (Yellow) Bulb (Green) Solenoid A+ Solenoid A-e Solenoid B Solenoid B- 24V+) PAV.) 24V 2AV.) 24V - 24V 24V 24V - 24V 24V Table 1 - PLC NAIS FP-0 1/0 Assignment Table Fig. 3-PLC NAIS FP-O Training Board

Step Description 1. Initial State: Homing 2.1 User presses Button PBO (X44) to RESET counter and HOME cylinders to retracted states. i.e. Sensors a0 (X40) and bo (X42) are activated. 2.2 All light bulbs turn off- e 2. User presses Button PBI (X45) Linear 2.3 Green Bulb (Y42) turns ON Actuator 2.4 Cylinder A extends (Y43) 2.5 Sensor al (X41) is activated 2.6 Cylinder A retracts (Y44) 2.7 Sensor a0 (X40) is activated 2.8 Cylinder B extends (Y45) 2.9 Sensor bl (X43) is activated 2.10 Cylinder B retracts (Y46) 2.11 Sensor bo (X42) is activated 2.12 Repeat the cycle (Steps 2.4 -2.11) 3 more times 2.13 Green Bulb (Y42) turns OFF and Red Bulb (240) turns ON 4 Table 2 - Requirement of Working Sequence Q.2 Refer to the information (Figure 1. Figure 2, Figure 3, Table 1, Table2), Group the motion sequence by the Cascade method. Design and write the NAIS FP-O PLC ladder diagram to do the working sequence, which is mentioned in Table 2. (35%) ii. Explain in details the design principle of your PLC program. (5%)