- Example 2 It Required To Transfer Water At A Rate Of 2 170 Kg Hr From A Storage Tank To A Process Vessel At 30 C Stora 1 (126.13 KiB) Viewed 27 times
Example 2 It required to transfer water at a rate of 2,170 kg/hr from a storage tank to a process vessel at 30 °C. Stora
-
- Site Admin
- Posts: 899603
- Joined: Mon Aug 02, 2021 8:13 am
Example 2 It required to transfer water at a rate of 2,170 kg/hr from a storage tank to a process vessel at 30 °C. Stora
Example 2 It required to transfer water at a rate of 2,170 kg/hr from a storage tank to a process vessel at 30 °C. Storage tank is at pressure 700 kPa a. What should be the optimum pipe size? From the following piping details: Determine pressure drop due to friction considering commercial steel pipe and Determine pressure drop due to pipe fittings by applying "equivalent pipe diameter" method. Total length of the pipe = 100 m, three 90° standard long elbow, two tee-entry from leg, two fully open gate valves, two half open globe vales-plug disk. Relative roughness of the pipe = [0.046/d;], where d; in mm. Take fluid density = 996 kg/m³ and viscosity = 0.89 mN-s/m²