Refer to Table 56.1-Factors for Computing Control Chart Limits (3 sigma) for this problem Sampling 4 pieces of precision

Business, Finance, Economics, Accounting, Operations Management, Computer Science, Electrical Engineering, Mechanical Engineering, Civil Engineering, Chemical Engineering, Algebra, Precalculus, Statistics and Probabilty, Advanced Math, Physics, Chemistry, Biology, Nursing, Psychology, Certifications, Tests, Prep, and more.
Post Reply
answerhappygod
Site Admin
Posts: 899603
Joined: Mon Aug 02, 2021 8:13 am

Refer to Table 56.1-Factors for Computing Control Chart Limits (3 sigma) for this problem Sampling 4 pieces of precision

Post by answerhappygod »

Refer To Table 56 1 Factors For Computing Control Chart Limits 3 Sigma For This Problem Sampling 4 Pieces Of Precision 1
Refer To Table 56 1 Factors For Computing Control Chart Limits 3 Sigma For This Problem Sampling 4 Pieces Of Precision 1 (36.38 KiB) Viewed 44 times
Refer To Table 56 1 Factors For Computing Control Chart Limits 3 Sigma For This Problem Sampling 4 Pieces Of Precision 2
Refer To Table 56 1 Factors For Computing Control Chart Limits 3 Sigma For This Problem Sampling 4 Pieces Of Precision 2 (50.26 KiB) Viewed 44 times
Refer to Table 56.1-Factors for Computing Control Chart Limits (3 sigma) for this problem Sampling 4 pieces of precision-cut wire (to be used in computer assembly) every hour for the past 24 hours has produced the following results: D Hour X R Hour X R Hour X R 1 0.58 13 19 3.31 1.61" 3.15 3.10 14 2.79 1.09 R Hour X 0.71" 7 3.05 1:23 8 2.55 1.48 9 2.92 1.21 10 2.75 1.17 11 2.93 2.76 0.42 12 3.07 0.35 3.12 1.13 0.00 1.33 16 2.55 1.13 3.49 3.18 0.41. 3,07 2.94 2.76 1.43 1.22 2.84 1.53 18 2.84 1.34 24 2.74 1.02 Based on the sampling done, the control limits for 3-sigma x chart are (round all intermediate calculations to three decimal places before proceeding with further calculations): Upper Control Limit (UCL;) = inches (round your response to three decimal places) Lower Control Limit (LCL) inches (round your response to three decimal places) Based on the x-chart, the wire cutting process has been The control limits for the 3-sigma R-chart are (round all intermediate calculations to three decimal places before proceeding with further calculations): Upper Control Limit (UCL) - inches (round your response to three decimal places). Lower Control Limit (LCLR)= inches (round your response to three decimal places) 2341016 3 5 FHBDTR 3.21 0.85 2.83 1.26 1.00 21 0.50 22 15 3.12 17 288888 20 23

Definition Sample Size, n 2 234 3 5 6 7 8 9 10 12 Mean Factor, A₂ 1.880 1.023 0.729 0.577 0.483 0.419 0.373 0.337 0.308 0.266 Upper Range, D4 3.268 2.574 2.282 2.115 2.004 1.924 1.864 1.816 1.777 1.716 Lower Range, D3 0 0 0 0 0 0.076 0.136 0.184 0.223 0.284
Join a community of subject matter experts. Register for FREE to view solutions, replies, and use search function. Request answer by replying!