Question 17: Consider the information in Figure 14. A urine sample from a non- smoking girl whose parents are heavy smok

Business, Finance, Economics, Accounting, Operations Management, Computer Science, Electrical Engineering, Mechanical Engineering, Civil Engineering, Chemical Engineering, Algebra, Precalculus, Statistics and Probabilty, Advanced Math, Physics, Chemistry, Biology, Nursing, Psychology, Certifications, Tests, Prep, and more.
Post Reply
answerhappygod
Site Admin
Posts: 899603
Joined: Mon Aug 02, 2021 8:13 am

Question 17: Consider the information in Figure 14. A urine sample from a non- smoking girl whose parents are heavy smok

Post by answerhappygod »

Question 17 Consider The Information In Figure 14 A Urine Sample From A Non Smoking Girl Whose Parents Are Heavy Smok 1
Question 17 Consider The Information In Figure 14 A Urine Sample From A Non Smoking Girl Whose Parents Are Heavy Smok 1 (20.94 KiB) Viewed 18 times
Question 17 Consider The Information In Figure 14 A Urine Sample From A Non Smoking Girl Whose Parents Are Heavy Smok 2
Question 17 Consider The Information In Figure 14 A Urine Sample From A Non Smoking Girl Whose Parents Are Heavy Smok 2 (99.09 KiB) Viewed 18 times
Question 17: Consider the information in Figure 14. A urine sample from a non- smoking girl whose parents are heavy smokers had an average peak area ratio of 1.25. Find the nicotine concentration (ug-L-') in the sample. [Do not type in the unit.]
The following method was used to determine the levels of nicotine (1) in the urine of smokers. A 1.00 cm³ sample of urine was placed in a 12 cm³ vial containing 0.7 g Na,CO, powder. After 5.00 ug of the internal standard 5-aminoquinoline (2) was injected, the vial was capped with a rubber septum. The vial was heated to 80°C for 20 minutes before an SPME needle was passed through the septum. The fibre was left in the headspace for 5 minutes. Then volatile substances were desorbed from the fibre at 250°C for 10 minutes in the GC injection port. During this time the column was held at 60°C while the analyte and internal standard were trapped at the beginning of the column. The column temperature was then raised to 260°C at 25°C min. The eluate was monitored by El-MS with SIM at ", 84 for nicotine and at ", 144 for the internal standard. All values are averages of duplicate measurements. NH₂ 1 2 Calibration y = 0.0064x + 0.0222 R' = 0.9956 A (nicotine) A (5-aminoquinoline) 100 150 250 Concentration (ug-L¹) 1.6 1.4 1.2 0.8 0.6 0.4 0.2 0 200
Join a community of subject matter experts. Register for FREE to view solutions, replies, and use search function. Request answer by replying!
Post Reply