Problems 2 and 3 refer to the floor plan shown in Fig. 2. S CI C2 C3 C4 CS 3 GI (typ.) C6 C7 C8 Given: L = 25' (typ.) an

Business, Finance, Economics, Accounting, Operations Management, Computer Science, Electrical Engineering, Mechanical Engineering, Civil Engineering, Chemical Engineering, Algebra, Precalculus, Statistics and Probabilty, Advanced Math, Physics, Chemistry, Biology, Nursing, Psychology, Certifications, Tests, Prep, and more.
Post Reply
answerhappygod
Site Admin
Posts: 899603
Joined: Mon Aug 02, 2021 8:13 am

Problems 2 and 3 refer to the floor plan shown in Fig. 2. S CI C2 C3 C4 CS 3 GI (typ.) C6 C7 C8 Given: L = 25' (typ.) an

Post by answerhappygod »

Problems 2 And 3 Refer To The Floor Plan Shown In Fig 2 S Ci C2 C3 C4 Cs 3 Gi Typ C6 C7 C8 Given L 25 Typ An 1
Problems 2 And 3 Refer To The Floor Plan Shown In Fig 2 S Ci C2 C3 C4 Cs 3 Gi Typ C6 C7 C8 Given L 25 Typ An 1 (52.68 KiB) Viewed 12 times
Problems 2 And 3 Refer To The Floor Plan Shown In Fig 2 S Ci C2 C3 C4 Cs 3 Gi Typ C6 C7 C8 Given L 25 Typ An 2
Problems 2 And 3 Refer To The Floor Plan Shown In Fig 2 S Ci C2 C3 C4 Cs 3 Gi Typ C6 C7 C8 Given L 25 Typ An 2 (17.53 KiB) Viewed 12 times
Problems 2 And 3 Refer To The Floor Plan Shown In Fig 2 S Ci C2 C3 C4 Cs 3 Gi Typ C6 C7 C8 Given L 25 Typ An 3
Problems 2 And 3 Refer To The Floor Plan Shown In Fig 2 S Ci C2 C3 C4 Cs 3 Gi Typ C6 C7 C8 Given L 25 Typ An 3 (9.29 KiB) Viewed 12 times
Problems 2 and 3 refer to the floor plan shown in Fig. 2. S CI C2 C3 C4 CS 3 GI (typ.) C6 C7 C8 Given: L = 25' (typ.) and S = 10 (typ.). So, the overall floor plan = 75' x 60' The beam width (bw) and depth (h) of B1 (typ.) are taken to be 10-in and 20-in, respectively. L SI (typ B1 (typ.) B1 (typ) C9 cio C11 C12 A typical girder, e.g., G1, has a width (b) of 12-in. GI (typ.) C13 C14 C15 C16 Fig. 2 - Floor Plan for Problems 2 & 3.
a Problem 2. The one-way slab, S1 (typ.), has a thickness of 5-in, cast with fé = 5,000 psi (normal weight concrete, 150 pcf. Bi = 0.8). No. 4 Gr-60 rebars are used as main (i.e., longitudinal) reinforcement, and No. 3 Gr-60 rebars are secondary (i.e., temperature and shrinkage, perpendicular to main) reinforcement, with a standard cover of %-in. No shear reinforcement is provided. The floor is subjected to a live load of 50 psf.
(10 points) What is nearly the amount of temperature and shrinkage reinforcement required per linear ft of the slab. Note No. 3 Gr-60 rebars are used. Round the spacing to the near y-in.