AaBbCcDdEe AaBbCcDdEe EE | == == = АавbccDC Аавьс Heading 1 Normal No Spacing Head A building has roof and occupied spac

Business, Finance, Economics, Accounting, Operations Management, Computer Science, Electrical Engineering, Mechanical Engineering, Civil Engineering, Chemical Engineering, Algebra, Precalculus, Statistics and Probabilty, Advanced Math, Physics, Chemistry, Biology, Nursing, Psychology, Certifications, Tests, Prep, and more.
Post Reply
answerhappygod
Site Admin
Posts: 899604
Joined: Mon Aug 02, 2021 8:13 am

AaBbCcDdEe AaBbCcDdEe EE | == == = АавbccDC Аавьс Heading 1 Normal No Spacing Head A building has roof and occupied spac

Post by answerhappygod »

 1
1 (67.24 KiB) Viewed 33 times
AaBbCcDdEe AaBbCcDdEe EE | == == = АавbccDC Аавьс Heading 1 Normal No Spacing Head A building has roof and occupied spaces (compartments). Occupied space is insulated, and roof space walls/ceiling has no insulation. The occupied-space floor is insulated by joist air space and flooring. Analysis tracks the temperature in the 2 spaces based on Newton's cooling law:roof-space temperature z(t), occupied space temperature y(t). Timet is in hours. hr1 k1,2 W.L HAHA Insulation coefficients Building width, length Height: occupied and roof spaces 0.05 x 6,0.8 5, 10 4,2.5 m ΕΕ m kuz reflect insulation quality for occupled and roof space. Smaller is better. For outside day-time temperature To = 8 and ground temperature TG = 0, assume initially heating is off: initial values at are y(0) = z[0) = To when a heater is turned on to provide qH = 6°C/hr rise. The occupied-space thermostat is set at 40°C. Newton's cooling law "temperature rate = k times temperature difference" is applied to surfaces: occupied-space floor, walls, ceiling, and roof space floor, ceiling: dy/dt = k, (TG - y) + k. (7-- y) + k, (2- y) + q. dz/dt = kz(y-2) +0.81T --z) Tasks [1] For constant roof-space temperature z = ze = 10, solve for the occupied-space temperature y(t). From your solution determine () how long (if ever) it takes to reach thermostat temperature and () the steady-state occupied-space temperature [2] Solve the 2 coupled equations and consider the solution as t— Is the thermostat requirement met? What insulation and/or heating are required to meet the thermostat requirement? [3] For a more realistic) cyclic daily temperature, 7+14 sin ft/12, re-solve the occupied space ODE for constant roof-space temperature z = 20 = 10. Compare the outcomes and consequences with your solution from (1) and suggest a practical approach to dealing with the occupied-space temperature variation indicated in the solution (3).
Join a community of subject matter experts. Register for FREE to view solutions, replies, and use search function. Request answer by replying!
Post Reply