The fully mixed activated sludge process is designed by using the kinetic formula. The amount of wastewater is 10000m3/d

Business, Finance, Economics, Accounting, Operations Management, Computer Science, Electrical Engineering, Mechanical Engineering, Civil Engineering, Chemical Engineering, Algebra, Precalculus, Statistics and Probabilty, Advanced Math, Physics, Chemistry, Biology, Nursing, Psychology, Certifications, Tests, Prep, and more.
Post Reply
answerhappygod
Site Admin
Posts: 899604
Joined: Mon Aug 02, 2021 8:13 am

The fully mixed activated sludge process is designed by using the kinetic formula. The amount of wastewater is 10000m3/d

Post by answerhappygod »

The fully mixed activated sludge process is designed by using the kinetic formula. The amount of wastewater is 10000m3/d,the dissolved BOD5 of influent is 120mg / L, and the dissolved BOD5of effluent is required to be less than 10mg / L. assuming that the sludge age is 10d and the MLVSS in the aeration tank is 2000mg / L, the kinetic constants obtained from the test are y = 0.60mgVSS/mg BOD5, Kd= 0.06d^-1,ks= 60mg / L (BOD5) and Vmax = 5.0d^-1.Try to determine the basic size of the aeration tank and as many operating parameters as possible
Join a community of subject matter experts. Register for FREE to view solutions, replies, and use search function. Request answer by replying!
Post Reply