Find the number of luminaires needed (both fractional number and then rounded off to nearest whole number) in an office

Business, Finance, Economics, Accounting, Operations Management, Computer Science, Electrical Engineering, Mechanical Engineering, Civil Engineering, Chemical Engineering, Algebra, Precalculus, Statistics and Probabilty, Advanced Math, Physics, Chemistry, Biology, Nursing, Psychology, Certifications, Tests, Prep, and more.
Post Reply
answerhappygod
Site Admin
Posts: 899604
Joined: Mon Aug 02, 2021 8:13 am

Find the number of luminaires needed (both fractional number and then rounded off to nearest whole number) in an office

Post by answerhappygod »

Find the number of luminaires needed (both fractional number and then rounded off to nearest whole number) in an office given the following formula and supplied information: Number of luminaires = (AWP x EWP ) / (lumens/lamp x lamps/luminaires x CU x LLF TOTAL) Where: Ewp = average maintained illuminance on the work plane Φ (TOTAL) = total system lamp lumen output CU = coefficient of utilization LLF TOTAL = Total light loss factor Awp = area of the work plane
Table 1 Ranges of Illuminances Type of Activity Reference Work Plane Lux Footcandles Public spaces with dark surroundings 20-30-50 2-3-5 Simple orientation for short temporary visits 50-75-100 5-7.5-10 General Lighting Throughout Spaces Working spaces where visual tasks are only occasionally performed 100-150-200 10-15-20 Performance of visual tasks of high contrast or large size 200-300-500 20-30-50 Performance of visual tasks of medium contrast or small size 500-750-1000 5-75-100 Illuminance on task Performance of visual tasks of low contrast or very small size 1000-1500-2000 100-150-200 Performance of visual tasks of low contrast and very small size over a prolonged period 2000-3000-5000 200-300-500 Illuminance on task, obtained by a combination of general and local Performance of very prolonged and exacting visual tasks H 5000-7500-10000 500-750-1000 Performance of very special visual tasks of extremely low contrast and small size 10000-15000- 20000 (supplementary lighting) 1000-1500-2000 1 ESNA Lighting Handbook Table 2: Coefficient of Utilization - All floor reflectances = 20% RCC% 80 80 80 70 70 70 50 50 RW% 70 50 30 70 50 30 50 30 RCR 0 .97 97 97 94 94 94 90 90 1 .89 86 .82 87 84 81 80 78 2 .82 76 .71 .80 74 70 71 68 .75 .67 .61 73 66 61 64 59 .69 60 54 68 59 53 57 52 .64 54 47 62 53 47 52 46 59 49 42 58 48 42 47 41 .55 45 38 54 44 38 43 37 51 41 34 50 40 34 39 34 31 36 31 48 38 31 47 37 45 35 29 44 34 28 34 28 7 8 9 10 Illuminance Category A B с D E F G
Join a community of subject matter experts. Register for FREE to view solutions, replies, and use search function. Request answer by replying!