In a Field’s test on two 230-V, 1.492 kW mechanically-coupled similar series motors, the following figures were obtained

Business, Finance, Economics, Accounting, Operations Management, Computer Science, Electrical Engineering, Mechanical Engineering, Civil Engineering, Chemical Engineering, Algebra, Precalculus, Statistics and Probabilty, Advanced Math, Physics, Chemistry, Biology, Nursing, Psychology, Certifications, Tests, Prep, and more.
Post Reply
answerhappygod
Site Admin
Posts: 899604
Joined: Mon Aug 02, 2021 8:13 am

In a Field’s test on two 230-V, 1.492 kW mechanically-coupled similar series motors, the following figures were obtained

Post by answerhappygod »

In a Field’s test on two 230-V, 1.492 kW mechanically-coupled
similar series motors, the following figures were obtained. Each
has armature and compole winding resistance of 2.4 Ω, series field
resistance of 1.45 Ω and total brush drop of 2 V. The p.d. across
armature and field was 230 V with a motor current of 10.1 A. The
generator supplied a current of 8.9 A at a terminal p.d. of 161 V.
Calculate the efficiency and output of the motor for this load.
[76.45%, 1.775 kW]